Home > Products > Multi-Purpose Smart Card System >
Access Controller System >
Network Access Control Management System
System Profile
TalenCa 9700NX Network Access Control Management System is a control system with powerful functions. It is equipped with technologies of computer, automatic control, network communication, smart card, sensing technique and electromechanical integration. As a result, it is the best program for modern intelligent buildings and communities to realize real-time safekeeping control and management. The system adopts international popular open structure so that it is compatible with any third-party system or equipment. Therefore, the high integration of the use’s system can be realized.
Main Functions of the System
* Multi-function
ccess control
Environment control (temperature control etc.)
General control (lift, parking lot, theftproof sensor, monitoring system)
* Support many kinds of control unit module (UPU)
TN9701 series access control unit module (DPU)
TN9730 series digital input control unit module (DIU)
TN9740 series digital input/output control unit module (DIO)
TN9750 series analog quantity input control unit module (AIU)
NCU network communication controller
* Hierarchy control structure
Control computer (CPC) is connected with system network controller (NCU) through RS232 interface.
NCU is connected with DPU by ET-BUS. Each NCU can be connected with 127
DPU at most. The length of bus line can reach 1.2 km without repeaters.
Control computers (CPC) are connected by Ethernet.
Long-distance control can be realized through phone-dialing network.
Main Functions of the System
Security management function. Any user can’t access the software system without legal password.
Perfect authorization management system. The levels of authorization management amount to 256 at most. Based on each functional menu, all managers can beauthorized respectively.
Locally add or cancel the unlocking card at real time.
Optional long-distance control module can realize long-distance authorization management so as to the database maintenance.
Optional long-distance control module can realize long-distance monitoring function.
Real-time displaying the opening or closing state of locks and the card-using records.
Function of attendance check, including records of entering and going out (only valid in the card system that needs card to go out ). All kinds of report forms and attendance report can be printed out.
At most 30 groups time tables with seven days a week can be set, and 8 special days and 2 temporary time tables can be set as well.
Complete event records, including access time, date, card No., and the time, section No. and site No. of the event.
Complete system operation records, including all the important operations, operators, operating details and the time.
System Constitution
Access control’s card reader (with the function of attendance check)
Access control module
Contactless smart card issuer
Comprehensive management software for host computer
Contactless smart card
Network controller
Cathodal lock or anodal lock
Gate’s magnetic switch
Button for going out
Backup power
PC mainframe, printer and operating system (Windows 98/NT/2000)
Power Supply
220VAC/50Hz+20%, the electric current in normal operation should be no more than 220mA.
Backup battery (optional) is the 20VDC/Ni-H one.
It can last 10-50 hours when the power is turned off (The power expenditure by the electrically controlled lock is not considered.)
Specifications
TN9701 access control unit: 160mm (length)x120mm (width)x77mm (height)
TR9701/TR9801 radio frequency smart card reader: 112mm (length)x145mm (width)x24mm (height)
Main Features of TN9701 Series Access Control Unit Module
*DPU is interlinked with unit control computer (CPC) through ET-BUS interface and NCU. Each CPC can manage 2048 DPUs at most to realize real-time access control management control. Optional long-distance control module can realize long-distance authorization management and monitoring function through telephone network.
*It adopts TEMIC contactless smart card or EM4001 contactless ID card of TEMIC Company in Germany, or MIFARE
contactless smart card of PHILIPS Company in Holland.
*The contactless smart card reader with the distance of 40cm-50cm as the card-reading distance can be equipped.
*Large-size and long-distance inductive antenna (50cm-100cm) can be equipped.
*The standard equipment can manage 100 users, and 8,000 users at most after expansion.
*At most 30 groups time tables with seven days a week can be set, and 8 special days such as holiday and 2 temporary time tables can be set as well.
*Each access control unit can be connected with one to four card readers. The length of the connecting line should be no more than 10m.
*Threatening code’s alarming function.
*Sensitive anti-passback control.
*Two independent optical-isolation terminals for inputting switching signals can realize the linkage with the signal of fire or stealing.
*One input terminal for the button of opening gate.
*One to three control output terminals can be selected. The load of each terminal should be no more than 220VAC/3A. It can realize the linkage control functions such as monitoring and lighting, and it can start or shut off the equipment at fixed time, such as the bell for starting or ending work, the state of being on or off of the electronic water heater and the control of the lighting system in the building etc.
*5,000 event records at most.
*1-4 series access controllers, which can satisfy different users.
*The length of connecting line to the card reader can amount to 500m. The design is quite safe. All input or output terminals have the ability to protect them from short circuit, overloading, line mistake and surge. Each functional unit in the access controller has independent power supply system so that the mutual interference is minimized.
* Optional intelligent network controller (NCU) with large-capacity buffer storage (4MB at most) can increase the transferring speed of the network so as to lighten the burden of CPC.
Main Features of TR-9701/9701S/9801/9801S Card Reader
*TR-9701/9701S can read TEMIC E5550/E5551/EM4001 cards and support the password accessing function of TEMIC cards.
*TR-9801/9801S can read Mifare One/Mifare Pro/Mifare light cards and support the password accessing function of Mifare cards.
*RS-485 interface allows some card readers to be connected in the way of bus line. 16 card readers at most can work in the way of parallel connection.
*The card-reading distance marked out is 6cm. The longest distance of connected line is 500m.
*TR9701/9801 have LCD displaying screen of 16x2 lines and keyboard. Support information input with keyboard (input password for example).
Main Features of TEMX-800X Contactless Smart Card Issuer
*It reads and writes contactless smart cards in the way of wireless interaction.
Comparing with the traditional contact smart card issuer, its security and stability are much better.
*It has RS-232C interface, which can realize the bi-directional data exchange with PC.
*It has the protocol of safety certification and secret communication so that the card issuer will not be illegally used.
*Hardware encryption algorithm inside can automatically encrypt the smart cards so that the security of the system is satisfactory.
*It adopts the clock module of high accuracy which is for industrial application made by Dallars Company in USA and its power is supplied by independent lithium battery so that the accuracy and stability of the interior clock is guaranteed.
*It adopts 220V/110V AC so that the application is convenient.
Main Features of NCU-1 Intelligent Network Controller
NCU-1 Intelligent Network Controller is the high-performance one produced by our company with high-speed CPU, high-speed buffer storage of super high capacity and highly accurate real-time clock system inside. Based on the standard ET-BUS protocol of our company, NCU-1 is interlinked with the control equipment of each subsystem to exchange data at real time, save the exchanged data in the high-speed buffer storage temporarily, and exchange the data with the service port management software in the managing computer through high-speed communication interface. As a result, the communication efficiency of the system is optimized.
Type of locks and Choosing
The locks for TalenCa 9700NX include cathodal lock, anodal lock, magnetic lock, glass clip lock and TalenCa series
interlinked/non-interlinked contactless smart card lock etc. Passage gate which can be opened at both sides usually
adopts anodal bolt lock. The gate opened at one side adopts magnetic lock. The internal door usually uses cathodal lock to cooperate with former lock. Magnetic lock is also an option for special conditions. If high security is required for the internal door, for example, the separating doors in apartment buildings, TalenCa series interlinked/non-interlinked contactless smart card lock can be used.
People’s Trace Displaying System
System Profile
People’s trace displaying system can display each person’s trace and the relevant time at real time by reading the information in all kinds of card readers such as access control system, patrol and attendance check system. It can control the people in some special occasions and help to find the person who is being looked for in the common occasions.
Contactless Smart Card Attendance Check/ Patrol Management System
System Profile
KX (TEMIC, EM4001 card)/880 (Mifare card) series contactless smart card attendance check management system is the new computer-controlled attendance check management system produced by our company. It is safe and convenient and fit for all kinds of enterprises. It can be connected with the interface of attendance check controller through ET-BUS and with the computer through NCU. It can count and collect the data of attendance check at real time or at fixed time and put out all kinds of statistics report forms. KX-800/880 can be individually used and can also be connected with computer through RS-232C interface, which can satisfy small enterprises. At most 2000 such systems can work together with ET-BUS in order to satisfy the requirement of large or medium scale enterprises. The flexible setting of attendance check parameters can satisfies all kinds of complex requirements of attendance check. KX-800/880 attendance check management system is connected with TalenCa 9700NX network access control system and XG-800/880 contactless smart card patrol system seamlessly to form the contactless smart card management system in buildings.
Main Features of the System
* KX-800/880 series contactless smart card attendance checker adopts LCD to display year, month, date and time, and the card number of the personnel when reading the card.
* It has the keyboard, with which common functions of simple management and inquiry can be realized.
* If the power is shut off, the record can be kept for over 10 years.
* The power for the clock in the attendance checker is supplied by the independent special lithium battery. If the electrical power is shut off, the clock will continue working for more than 10 years so that the time needn’t resetting.
* Several fixed time of starting or ending work, off-day of the week and holidays can be set randomly according to the conditions of the departments or groups.
* Situation of absence from duty can be input manually so that different conditions such as sick leave, private affair leave, business trip and work done outside the office etc. can be accurately recorded.
* The situation of going out during working time can be input manually so that the hours or days of sick leave or private affair leave can be recorded.
* Overtime work can be automatically saved according to the card-reading record. The time (number of hour) of any event can be modified to avoid false overtime work record.
* It can list the specific attendance record of any person at any appointed time.
* The table will list his or her records of starting work, leaving, work number, being late, leaving early, private affair leave, sick leave, business trip and overtime work etc., and report forms can also be printed out.
* It can list the attendance check report of any department at any appointed time. The table will list the times of being late, leaving early, the total of sick leave, private affair leave and overtime work (number of hour), due work days and real attendance days of any person in the department, and report forms can also be printed out.
* The communication distance between the attendance checker with RS-232C interface and the computer without repeaters should be no more than 30m.
* One more repeater allows more distance of 1,200m.
* The communication distance between the attendance checker with ET-BUS interface and the computer without repeaters should be no more than 1,200m.
* One more repeater allows more distance of 1,200m.
* The distance of reading card is 3~8cm. The reading time is less than 0.5 second.
System Constitution
* KX-800/880 series contactless smart card attendance checker.
* PW-800 attendance check controller, including 10-hour UPS.
* TEMIC contactless smart card/EM4001 contactless ID card or MIFARE contactless smart card.
* The attendance checker with ET-BUS interface should be equipped with NCU network controller.
* Each network controller can be interlinked with 127 attendance checkers at most.
* Software for KX-800 attendance check management system (Windows 98/NT/2000).
* Attendance check management computer, which should be prepared by the users themselves and can be used with other management computers, and printer.
FunctionsoffPatrollSyste
The system inquires about the card-reading information which record the security personnel’s work in and out of the building at specific period of time, deals with the data and automatically makes report forms so as to realize patrol management.
Multi-Purpose Smart Card System Access Controller System
Copyright 2007 Easthouse Electrical Co., Ltd. All right reserved